《分流不分流進(jìn)樣口介紹》由會(huì)員分享,可在線閱讀,更多相關(guān)《分流不分流進(jìn)樣口介紹(14頁珍藏版)》請(qǐng)?jiān)谘b配圖網(wǎng)上搜索。
1、Slide #1 6850/6890 Split AnimationSplit/Splitless Inlet - Component IdentificationSeptum LinerLiner O-Ring Gold Seal Capillary Column5/4/00 Slide #2 6850/90 Split/Splitless Inlet - Component IdentificationSeptum SEPTUM PURGEVENT Inlet SplitPort Slide #3 6850/90 Split Animation - Default ConditionsFL
2、OWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORPURGEVALVEOPENTOTAL FLOWCONTROL LOOP SPLITVENTGOLD SEALINPUTPRESSURE PROPORTIONALVALVE 280 PSI 0 ML/MIN SPLIT VENTTRAP 0PSI Slide #4 6850/90 Split Animation - Total Flow SettingFLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGE
3、REGULATORPURGEVALVEOPENTOTAL FLOWCONTROL LOOP SPLITVENT205 ML/MINGOLD SEALINPUTPRESSURE PROPORTIONALVALVE 280 PSI PRIMARY FLOW PATHREDUCED FLOW PATH205ML/MIN SPLIT VENTTRAP 0PSI Slide #5 6850/90 Split Animation - Inlet Pressure SettingFLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULAT
4、ORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPGOLD SEALINPUTPRESSURE PROPORTIONALVALVE 280 PSI PRIMARY FLOW PATHREDUCED FLOW PATH205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN PRESSURIZED GAS BACK PRESSURE CONTROL LOOP Slide #6 6850/90 Split Ready for Injection Animation
5、 FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPINPUTPRESSURE PROPORTIONALVALVE 280 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1Mode: SplitTemp 250 250Pres
6、sure 10.0 10.0Split Ratio 100 Split Flow 200Tot Flow 205.0 205.0Gas Saver OFF Slide #7 6850/90 Split Insert Syringe Animation FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPGOLD SEALINPUTPRESSURE PROPORTIONALVALVE 280 PSI 205ML/MIN
7、 SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1 Slide #8 6850/90 Split Inject Sample Animation FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPGOLD SEALINPUTPRESSURE PROPOR
8、TIONALVALVE 280 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1 Slide #9 6850/90 Split Sample Vaporizes Animation FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL L
9、OOPGOLD SEALINPUTPRESSURE PROPORTIONALVALVE 280 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1Glass Wool Slide #10 6850/90 Split Sample is Split - Animation Good Liner Design?FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTU
10、M PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPINPUTPRESSURE PROPORTIONALVALVE 280 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1Smaller O.D. LinerOpen Split Flow PathGlass Positioning BeadGlassWool Tapered L
11、inerAgilent SplitLiner - 5183-4647 Slide #11 6850/90 Split Split Continues Animation FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPINPUTPRESSURE PROPORTIONALVALVE 280 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN F
12、LOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1 Slide #12 6850/90 Split Split is Complete Animation FLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPINPUTPRESSURE PROPORTIONALVALVE 280 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPL
13、ITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1 Slide #13 6850/90 Split Sample is separated Animation and DetectedFLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURGEVALVEOPENTOTAL FLOWCONTROL LOOPINPUTPRESSURE PROPORTIONALVALVE 280
14、 PSI 205ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT200 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1 Slide #14 6850/90 Split Gas Saver - Set to 55 ml/min Animation After the Injection is completeFLOWSENSOR PROPORTIONALVALVE 1 PRESSURESENSOR SEPTUM PURGEREGULATORFIXED 3ML/MINPURG
15、EVALVEOPENTOTAL FLOWCONTROL LOOPINPUTPRESSURE PROPORTIONALVALVE 280 PSI 55ML/MIN SPLIT VENTTRAP 10PSI SPLITVENT50 ML/MIN COLUMN FLOW2 ML/MIN BACK PRESSURE CONTROL LOOPSplit Ratio - 100:1Mode: SplitTemp 250 250Pressure 10.0 10.0Split Ratio 100 Split Flow 200Tot Flow 205.0 205.0Gas Saver ONSaver Flow 50.0Saver Time 0.5