電熱水暖恒溫自動(dòng)控制系統(tǒng)的設(shè)計(jì)
電熱水暖恒溫自動(dòng)控制系統(tǒng)的設(shè)計(jì),電熱,水暖,恒溫,自動(dòng)控制系統(tǒng),設(shè)計(jì)
外文翻譯電熱水器安裝使用說明書為了避免熱水器過熱或超壓所帶來的危險(xiǎn),當(dāng)?shù)赜嘘P(guān)規(guī)定可能要求安裝過熱和超壓保護(hù)裝置,但是,至少也要安裝一個(gè)由國(guó)家推薦的檢驗(yàn)實(shí)驗(yàn)室認(rèn)證的降溫減壓安全閥,并且在使用過程中,要對(duì)這些合格的裝置進(jìn)行定期的檢查和維護(hù),確認(rèn)符合美國(guó)燃?xì)鈪f(xié)會(huì)發(fā)布的《美國(guó)熱水供應(yīng)系統(tǒng)自動(dòng)燃?xì)怅P(guān)閉裝置安全閥規(guī)定》中的 ANSI Z21.22 要求。這種安全法必須標(biāo)注不能超過的最大設(shè)置壓力和熱水器的最大工作壓力。這種閥門每小時(shí)排放高溫蒸汽 BTU 的能力必須超過熱水器每小時(shí)產(chǎn)生熱量的能力。 在熱水器上用于安裝安全閥的接口處安裝安全閥,并將安全閥朝向或連接管道使得安全閥的排泄口距離地漏口高 6 英寸高度的地方,或者任何結(jié)構(gòu)地面下方,不得接觸任何電源部件。在熱水起儲(chǔ)水罐和安全閥之間不需要安裝任何閥門。排泄管道必須能夠完全容納安全閥和排泄管的排泄物。在任何情況下,都不得限制或減少排泄管道的尺寸。排泄管道的終端開口必須靠近地漏或其他不會(huì)堵塞或凍結(jié)的地方。不要對(duì)排泄管攻螺紋、堵塞子或加蓋。在排泄管道出口和地漏之間要留下 6 英寸的距離。安裝完所有水管后,打開主要供水閥門,將熱水器儲(chǔ)水罐注滿水。打開幾個(gè)熱水水龍頭,讓熱水管道中的氣體在注水過程中排放出來。當(dāng)水從水龍頭流出時(shí),關(guān)閉水龍頭,并檢驗(yàn)管路系統(tǒng)中是否有泄漏現(xiàn)象。電路連接:在進(jìn)行電路連接之前,請(qǐng)確認(rèn)熱水器是否已經(jīng)注滿水,冷水進(jìn)口閥門是否處于開啟狀態(tài)。在連接前要檢驗(yàn)額定面板上的電路圖。本電熱水器的生產(chǎn)以及電路的連接設(shè)計(jì)都符合美國(guó) UL 認(rèn)證要求??梢詫?duì)溫度控制裝置進(jìn)行人工設(shè)置,可根據(jù)設(shè)定的溫度自動(dòng)開關(guān)電源。本款電熱水器還在工廠就預(yù)先安裝了能夠在溫度控制裝置失效的情況下切斷全部電源的裝置。溫度控制裝置在工廠就預(yù)先設(shè)置,并且按照電路圖所示進(jìn)行布線,固定在熱水器頂部面板入口內(nèi)。操作方法:在打開電源開關(guān)之前,要確保熱水器處于滿水狀態(tài),冷水進(jìn)水閥門處于開啟狀態(tài)。如果在通電的過程中,電加熱棒沒有浸泡在水中,可能會(huì)導(dǎo)致電加熱棒燒壞。打開電源開關(guān)后,本電熱水器的完全自動(dòng)操作。溫度控制器預(yù)先設(shè)置在"熱" 的位置,這種設(shè)置所提供的熱水水溫最高為49℃,可以避免燙傷事故的發(fā)生。注意:人體在 57℃水溫下持續(xù) 5 秒鐘,將會(huì)導(dǎo)致燙傷。對(duì)于管道系統(tǒng)內(nèi)的任何水龍頭,本熱水器均可提供高溫?zé)崴T谑褂脽崴畷r(shí),一定要小心,要注意防止?fàn)C傷事故的發(fā)生。某些設(shè)備需要高溫?zé)崴ɡ缦赐霗C(jī)和自動(dòng)洗衣機(jī)) 。為了防止可能發(fā)生的燙傷事故,請(qǐng)?jiān)跓崴艿老到y(tǒng)上安裝一個(gè)防燙傷調(diào)節(jié)閥門。這種閥門能夠通過調(diào)節(jié)冷熱水的混合比例來降低排放出的熱水的溫度。如果需要安裝這種閥門,請(qǐng)向有用資格證書的管道工咨詢。 通過調(diào)節(jié)溫度控制器,可以改變熱水器的水溫設(shè)置。在調(diào)節(jié)溫度控制器的溫度設(shè)置之前,請(qǐng)首先關(guān)閉電源開關(guān),切斷電源。將熱水器上的入口面板拆卸下來,把溫度控制器的外部絕緣層拿下來。使用螺絲刀移動(dòng)溫度控制器的指示器將溫度調(diào)節(jié)到自己所需要的溫度,然后把絕緣層重新放在原先的位置,確保溫度控制器被絕緣層完全包裹,接著把入口面板重新蓋上。這時(shí)熱水器可以重新工作,可以重新打開電源開關(guān)。 安全提示:對(duì)工廠原裝的熱水器增加電源功率和/或增加電源電壓可能導(dǎo)致熱水器和/或電路系統(tǒng)產(chǎn)生變化。對(duì)電熱水器未經(jīng)授權(quán)的更改可能會(huì)對(duì)生命和財(cái)產(chǎn)造成危害,而且也導(dǎo)致質(zhì)量保證條款失效。在對(duì)熱水器進(jìn)行更動(dòng)之前,請(qǐng)與當(dāng)?shù)亟?jīng)銷商和供電部門聯(lián)系。 為了便于熱水器的現(xiàn)場(chǎng)安裝和能源的節(jié)約,冷水出口和熱水出口接頭組件都在工廠安裝。不要拆卸這些接頭組件。 熱水器上的水連接管徑都是 3/4"(俗稱:6分管)錐管螺紋接頭。 安全閥排泄管終端距離地漏高度為 152mm。 如果使用焊接管道,不要在熱水器頂部的螺紋接頭上加熱。在將熱水器接頭的轉(zhuǎn)接頭與水管系統(tǒng)連接之前,先把轉(zhuǎn)接頭焊接在水管系統(tǒng)上。如果螺紋接頭包含塑料襯墊,則不要在這種螺紋接頭上焊接。 注意:如果把溫度控制器的溫度調(diào)節(jié)到高于工廠預(yù)置的溫度,將可能導(dǎo)致嚴(yán)重的燒傷和消耗更多的能源。水溫越高,燙傷的危險(xiǎn)就越高。如果需要把熱水器的水全部排干,應(yīng)該首先關(guān)閉電源開關(guān),關(guān)閉冷水進(jìn)口閥門,打開熱水水龍頭讓空氣進(jìn)入管道系統(tǒng),并且打開排水閥。排水閥上有螺紋,可連接標(biāo)準(zhǔn)軟管。對(duì)于櫥柜類型熱水器,前部面板必須拆卸下來,以便連接排水閥。注意:長(zhǎng)期(一般是兩星期以上)沒有使用的熱水器所連接的熱水管道系統(tǒng)可能會(huì)產(chǎn)生氫氣。氫氣是特別易燃的氣體。在這種情況下,為了避免傷害事故的發(fā)生,建議在打開熱水器的電源開關(guān)之前,廚房熱水水龍頭要先打開幾分鐘。如果有氫氣存在,在水流動(dòng)的時(shí)候,可能會(huì)有異常的聲響好像有空氣從管道內(nèi)排出。這時(shí),在開啟的水龍頭附近不能吸煙或由其它明火。維護(hù):如果供水中斷,必須立即關(guān)閉電源。在冰凍的季節(jié),如果住宅沒有人居住,應(yīng)該關(guān)閉熱水器電源、水源,將熱水器內(nèi)的水全部排光,以免在熱水器儲(chǔ)水罐內(nèi)出現(xiàn)結(jié)冰現(xiàn)象。為了保證熱水器熱效率達(dá)到最佳狀態(tài),延長(zhǎng)儲(chǔ)水罐的使用壽命,要把內(nèi)膽內(nèi)的水排干凈,使得排水閥流出的水是清水。至少每個(gè)月要排水一次。如果沒有這樣做,可能會(huì)導(dǎo)致熱水器運(yùn)轉(zhuǎn)有噪音,在內(nèi)膽底部沉淀石灰和水垢。檢查降溫減壓安全閥是否被石灰堵塞。反復(fù)扳動(dòng)安全閥的把手幾次,直到安全閥能夠正常泄水,操作靈活,并且沒有泄漏。安全事項(xiàng):扳動(dòng)降溫減壓安全閥把手,熱水將在壓力下釋放出來。要確保任何釋放出來的熱水不會(huì)導(dǎo)致任何人體傷害或財(cái)產(chǎn)損失。應(yīng)該定期檢查陽(yáng)極棒,為了延長(zhǎng)熱水器的使用壽命,在必要時(shí),更換陽(yáng)極棒。 服務(wù):當(dāng)熱水器內(nèi)的熱水溫度超過 88℃時(shí),熱水器上的超高溫自動(dòng)跳閘裝置會(huì)自動(dòng)切斷電源,也可以人工切斷電源。如果經(jīng)過合理的時(shí)間,仍然沒有產(chǎn)生熱水,請(qǐng)檢查保險(xiǎn)絲是否燒斷。如果保險(xiǎn)絲正常,請(qǐng)給維修人員打電話,讓維修人員在重新設(shè)置超高溫控制裝置之前,全面檢查包括溫度控制器在內(nèi)的全部元件。情與當(dāng)?shù)氐墓艿拦зR電力供應(yīng)公司聯(lián)系,更換配件或任何您認(rèn)為有問題的部件。請(qǐng)要求廠家和經(jīng)銷商檢驗(yàn)所更換的配件是否符合要求。為了延長(zhǎng)內(nèi)膽使用壽命,本熱水器安裝了組合型陽(yáng)極棒/熱水出口螺紋接頭。這種陽(yáng)極棒因定期檢查,如果需要的話要進(jìn)行更換。如果需要有關(guān)更換陽(yáng)極棒的信息資料,請(qǐng)與面板上的廠商聯(lián)系。水的軟化裝置可能增加陽(yáng)極棒的損耗。如果 使用軟化(或經(jīng)過磷酸鹽處理)的水,應(yīng)該更加經(jīng)常檢查陽(yáng)極棒。 本熱水器采用金屬鎂陽(yáng)極棒,有利于延長(zhǎng)內(nèi)膽的使用壽命。無論什么原因拆卸這種陽(yáng)極棒,都使得本熱水器的質(zhì)量保證無效。ELECTRIC WATER HEATER Installing and Operating InstructionsThe reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the Requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22, available from the American Gas Association, 1515 Wilson Blvd., Arlington, VA 22209. This valve must be marked with a maximum set pressure not to exceed the marke working pressure on the water heater. This valve must also have an hourly rated temperature steam BTU discharge capacity not less than the hourly input rating of the water heater. Install the valve into the opening provided and marked for this purpose in the water heater, and orient it or provide piping so that any discharge from the valve will exit only within 6 inches above, or at any distance below the structural floor and cannot contact any live electrical part. No valve is to be placed between the relief valve and tank. The discharge line must be installed to allow complete drainage of both the relief valve and the discharge line. The discharge line must not be restricted or reduced in size under any circumstances. The end of the discharge line opening should terminate near a floor drain or other suitable location not subject to blocking or freezing. DO NOT thread, plug or cap the discharge line. Leave an air gap of approximately six (6) inches between the end of the discharge line and a drain pan.After the installation of all water lines, open the main water supply valve and fill the heater. Open several hot water faucets to allow air to escape from the system while the heater if filling. When water passes through the faucets, close them and check for possible leaks in the system.ELECTRICAL CONNECTIONS:Before any electrical connections are made,be sure that the heater is full of water and that the valve in the cold water supply line is open. Check the rating plate and wiring diagram before proceeding. This electric water heater was built and wired in accordance with the Underwriters' Laboratories' testing approvals requirements. The temperature limiting device is of the manual reset,trip-free type and has been factory installe to interrupt all ungrounded power supply conductors in the event of thermostat failure. Thermostats are factory set and wired in accordance with the wiring diagram fastened to the inside of the top access panel.The dealer in your area ordered this heater wired at the factory to comply with existing area codes, but local utility codes may require or allow other circuity. Consult your local power company to determine the correct electrical hook-up in order to meet local utility and building codes and in order to obtain the most economical rates. Also check to find out if you are required to obtain a permit before starting the installation. The following chart shows the recommended fuse size for the maximum heat wattage. The maximum wattage and rated voltage are shown on the heater data plate.The heater must be well grounded. A green ground screw is provided at the electrical connection point for connecting a ground wire.OPERATION:Before closing the switch to allow electric current to flow to the heater, make certain that the heater is full of water and that the cold water inlet valve is open. Complete failure of the heating elements will result if they are not totally immersed in water at all times. When the switch is closed, the operation of this electric water heater is automatic The thermostats are preset to the "HOT" setting to provide a water temperature of approximately 120oF to reduce the risk of scald injury.CAUTION: Scalding may occur within five (5) seconds at a temperature setting of 135oF.This water heater is capable of delivering high temperature hot water at any faucet in the system. Care must be taken whenever using hot water to avoid scalding injury. Certain appliances require high temperature hot water (such as dishwashers and automatic clothes washers). In order to prevent potential scald injury, install an antiscald tempering valve in the water system. Valves for reducing point of discharge temperature by mixing cold and hot water in branch water lines are available. A qualified plumber should be consulted.The temperature of the water can be changed by adjusting the thermosta Before any work is done on the heater, disconnect all power to the heater by opening the switch at the main electrical circuit breaker of fuse box. Remove the access panels or front panel on table tops, fold the insulation outward away from the controls. Set the thermostats to the desired water temperature using a screw driver to move the thermostat pointer, replace the insulation making sure that the controls are well covered and that the plastic terminal shield has not been displaced; then replace the access panel. The heater is now ready for operation and the main switch can be closed. For Your Safety: Increasing the wattage and/or voltage from factory original equipment can require changes to the water heater and/or the electric service. Unauthorized modification of the water heater may create a hazard to life and property and will nullify the warranty. Contact your dealer or utility company before making any changes.CAUTION: INCREASING THE THERMOSTAT SETTING ABOVE THE PRESET TEMPERATURE MAY CAUSE SEVERE BURNS AND CONSUME EXCESSIVE ENERGY. HOTTER WATER INCREASES THE RISK OF SCALD INJURY.When necessary to completely drain the heater, shut to off the electric power supply to heater, close cold water inlet, open a hot water faucet to allow air to enter the system and open the drain valve, which is threaded to receive a standard hose coupling. On Table Top models, the front panel must be removed to gain access to the drain valve.CAUTION: Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time (generally two weeks or more.) Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open.MAINTENANCE:Shut off the electric power whenever the water supply is turned off. Shut off the electric power, water supply and drain the heater completely to prevent freezing whenever the building is left unoccupied during the cold weather months. In order to insure efficient operation and long tank life, drain the heater through the drain valve until water runs clear. Drain it at least once a month. Failure to do this may result in noisy operation and lime and sediment buildup in the bottom of the tank. Check the temperature-pressure relief valve to insure that the valve has not become incrusted with lime. Lift the lever at the top of the valve several times until valve seats properly without leaking and operates freely.SAFETY WARNING: When lifting lever of temperature/pressure relief valve, hot water will be released under pressure. Be certain that any released water does not result in bodily injury or property damage. The magnesium anode rod should be inspected periodically and replaced when necessary to prolong tank life.SERVICE:The manual reset, trip-free temperature limiting devices on this heater will cut off all power to heater if temperature of water exceeds 190oF. If there is no hot water after a reasonable period of time, check the main fuse box. In the event that the fuses have not blown, call a serviceman; have him check the entire circuit including the elements and thermostats before resetting the temperature limiting device. Heater must be disconnected from power supply before servicing switch. Consult the plumber or electric service company in your area for all service,replaceme parts or any questions you might have regarding this heater. Insist on factory inspected and approved replacement parts.A combination anode rod/hot water outlet nipple has been installed to extend tank life. This rod should be inspected periodically and replaced when necessary. Contact manufacturer listed on rating plate foreplacement anode information. The use of a water softener may increase the speed of anode consumption. More frequent inspection of the anode is needed when using softened (or phosphate treated) water.
收藏
編號(hào):146830
類型:共享資源
大?。?span id="zuq5qwn" class="font-tahoma">897.80KB
格式:RAR
上傳時(shí)間:2017-10-26
100
積分
- 關(guān) 鍵 詞:
-
電熱
水暖
恒溫
自動(dòng)控制系統(tǒng)
設(shè)計(jì)
- 資源描述:
-
電熱水暖恒溫自動(dòng)控制系統(tǒng)的設(shè)計(jì),電熱,水暖,恒溫,自動(dòng)控制系統(tǒng),設(shè)計(jì)
展開閱讀全文
- 溫馨提示:
1: 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
2: 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
3.本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
5. 裝配圖網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
裝配圖網(wǎng)所有資源均是用戶自行上傳分享,僅供網(wǎng)友學(xué)習(xí)交流,未經(jīng)上傳用戶書面授權(quán),請(qǐng)勿作他用。